Configuring NAT66 on ScreenOS

I recently had to deploy redeploy an old NetScreen 5GT to segregate a production LAN and create a small lab network. The production LAN has a routable IPv6 /64 prefix, delivered via a Hurricane Electric IPv6 tunnel. The lab network also required IPv6 connectivity. We also recently obtained a /48 prefix from Hurricane Electric, so I could have just assigned a /64 from that to the lab network and routed it via the 5GT. However, this 5GT gets moved around to various different networks, including trade show networks. As such, the untrust interface of the 5GT needed to be auto-configuring, so that it would obtain an IPv6 prefix from router advertisements on whichever LAN it was connected to. This also meant that assigning a /64 from our Hurricane Electric /48 prefix was out of the question.

The first step is to enable IPv6 support on your device, if it isn’t already:

set envar ipv6=yes
save
reset save-config yes

After restarting your device, you should find that IPv6 configuration options are available, and the web UI will also have additional pages and config options. Continue reading “Configuring NAT66 on ScreenOS”

Retrieving NetScreen/SSG config via scp

There are a couple of prerequisites before you can copy the config from a NetScreen or SSG via scp. First, obviously ssh and scp need to be enabled:

set ssh version v2
set ssh enable
set scp enable

And of course, you need to enable ssh management on the interface you’re going to connect to the device on:

set interface ethernet0 manage ssh

Once that has been done, from your PC, try the following:

scp netscreen@device-hostname:ns_sys_config ssg.cfg

And you should then have a file called ssg.cfg in that directory. Once again, simple when you know how.

It is also possible to load RSA/DSA keys against ScreenOS usernames, so that password-less login for ssh/scp can be utilised, allowing this method to form the basis of automated config backups.